1cP-AL-LAD 150mcg Blotters
$5.62
1cP-AL-LAD 150mcg Blotters (1-cyclopropanecarbonyl-6-allyl-6-nor-lysergic acid diethylamide hemi-L-tartrate) are premium, highly standardized absorbent matrices engineered specifically for advanced laboratory analysis, structural degradation mapping, and in vitro receptor affinity profiling. Serving as a crucial analytical reference standard within the novel substituted lysergamide chemical family, this compound combines an N1-cyclopropanecarbonyl group with an N6-allyl substitution on the core ergoline framework. This complex architecture allows investigative teams to study unique ligand binding kinetics with extreme accuracy. The high-density cellulose blotter configuration provides superior structural stability, preventing the sample mass loss and rapid environmental decomposition typically encountered when handling raw microgram-scale powders. Synthesized under meticulous quality control standards by Metric Lab Source, each batch maintains a verified baseline purity of 99% or greater for the active compound. This premium purity level safeguards your high-performance automated analytical instruments from baseline distortion or chemical contamination.
Physical and Chemical Properties
-
Chemical Characterization: Novel Substituted Lysergamide Derivative / Ergoline Core Framework.
-
Format Specification: High-absorption cellulose paper blotters infused with a 150mcg active dose.
-
Chemical Purity Index: $\ge 99.0\%$ certified purity of the active core 1cP-AL-LAD molecule.
-
Molecular Weight: Approximately $419.5\text{ g/mol}$ (as a free base core matrix).
-
Molecular Formula: $\text{C}_{26}\text{H}_{33}\text{N}_3\text{O}_2$ (Active Reagent Base Component)
-
Solubility Profile: Active material dissolves cleanly out of the paper substrate using standard laboratory polar organic solvents like methanol, ethanol, or acetonitrile.
-
Storage Protocols: Store inside an airtight, moisture-proof container within a dark chemical repository held between 2°C and 8°C, isolated completely from UV exposure, extreme heat, and ambient moisture.
Buy 1cP-AL-LAD 150mcg Blotters Research Chemical online USA, Europe and Worldwide
Introduction
The continued progression of modern neuropharmacological mapping, analytical biochemistry, and forensic toxicology relies on access to highly stable, structurally authenticated reference compounds. The 1cP-AL-LAD 150mcg Blotters configuration has emerged as a fundamental standard for academic and industrial laboratories investigating structure-activity relationships (SAR) within the lysergamide family. By introducing a cyclopropanecarbonyl alkyl chain at the N1 position alongside an allyl group substitution at the N6 position of the core ergoline ring structure, this chemical serves as an essential comparative model to understand how dual molecular modifications impact stability, ligand binding properties, and enzymatic cleavage in vitro. Delivering the active agent bound uniformly within a solid cellulose paper matrix provides excellent stability over time and keeps it shielded from rapid ambient oxidation, while the grid markings assist in precise physical sectioning during laboratory preparation. When you choose to buy 1cP-AL-LAD 150mcg Blotters from Metric Lab Source, you are securing an exceptional, analytical-grade reagent engineered specifically to accelerate scientific workflows and ensure high-fidelity laboratory data.
Key Features & Benefits
-
Calibrated Micro-Unit Precision (150mcg): Pre-infused blotters eliminate the manual errors, mass loss, and cross-contamination hazards of weighing raw microgram powders.
-
Uncompromising 99% Chemical Purity: The active core molecule in our blotters is synthesized independently to a baseline exceeding 99%, ensuring your analytical readings remain completely free from baseline distortion or unverified synthesis byproducts.
-
High Experimental Reproducibility: By ensuring a clean structural baseline entirely devoid of synthetic degradation products, this 99% pure 1cP-AL-LAD 150mcg Blotters formulation ensures that cross-batch assays yield consistent, verifiable, and peer-review-ready datasets.
-
Unique N1/N6 Structural Fingerprint: Allows research groups to benchmark complex structural variations, expanding forensic library detection capabilities for substituted ergoline derivatives.
-
Secure and Completely Discreet Shipping: All shipments are dispatched through protected, fully unbranded logistical streams, utilizing specialized vacuum-sealing protocols to maintain absolute institutional privacy.
Product Specifications
| Parameter | Specification Details |
| Product Name | 1cP-AL-LAD 150mcg Blotters |
| Chemical Category | Substituted Ergoline / Lysergamide Derivative |
| Active Quantity | 150mcg active compound per individual blotter unit |
| Purity Threshold | $\ge 99.0\%$ active core mass (HPLC, Mass Spectrometry validated) |
| Physical Form | High-density perforated cellulose paper blotters |
| Intended Applications | In vitro assays, receptor affinity tracking, forensic library profiling |
Applications & Usage
The integration of 1cP-AL-LAD 150mcg Blotters for research serves key needs within structural chemistry, molecular pharmacology, and toxicological screening libraries. Because it contains a distinct cyclopropanecarbonyl group attached directly to the indole nitrogen coupled with an allyl group substitution on the N6 nitrogen of the lysergic acid ring system, it allows researchers to study how changing the layout of multiple hydrophobic chains affects structural interactions at 5-HT (serotonin) receptor sites in vitro.
The solid absorbent paper format is perfectly suited for exact liquid extraction assays, colorimetric screening, and automated high-throughput mass profiling. Lab personnel can use standard chemical solvents to dissolve the active compound out of the paper substrate, preparing consistent solutions for high-performance liquid chromatography or electrochemical analysis.
Purity & Testing
At Metric Lab Source, chemical accuracy represents the fundamental pillar of our global operations. Every single production run of our 99% pure 1cP-AL-LAD 150mcg Blotters undergoes a strict, multi-tiered verification sequence before being approved for release to the scientific community.
Before the active substance is laid onto the blotter substrate, the raw compound is thoroughly checked via High-Performance Liquid Chromatography (HPLC) to guarantee an uncompromised purity index and uniform chemical distribution. We continuously verify the absolute structural identity and spatial arrangement of the molecular matrix using Mass Spectrometry (MS) and Nuclear Magnetic Resonance (NMR) spectroscopy, ensuring your laboratory receives a pristine standard that stands up to the most rigorous peer-reviewed auditing.
Safety & Handling Guidelines
This compound is an analytical-grade reagent and must be handled strictly by qualified professionals inside a certified laboratory setting. Standard Operating Procedures (SOPs) mandate the use of appropriate personal protective equipment (PPE), including chemical-resistant nitrile gloves, protective laboratory coats, and safety goggles. While the blotter matrix effectively stops inhalation risks, skin contact must be strictly avoided to prevent accidental absorption. Perform all extractions, modifications, and liquid dilutions inside a certified chemical fume hood. Avoid any contact with eyes, skin, or clothing. In case of accidental exposure, flush the area immediately with clean water and follow your facility’s environmental health and safety protocols.
Global Shipping & Discreet Delivery
Acquiring critical reference materials should never expose your laboratory to logistical bottlenecks or administrative complications. Metric Lab Source has perfected an advanced global transport framework to ensure rapid, dependable, and highly discreet delivery across the United States, Europe, and international research facilities.
Your order is sealed using industrial-strength, multi-layered vacuum sheets that secure the blotters from atmospheric variations while keeping the parcel entirely odor-neutral. The outward packaging is entirely plain and unbranded, featuring no chemical nomenclature, no structural drawings, and no reference to our brand name. All tracking numbers are handled over secure protocols, and international customs paperwork is processed using standard harmonized chemical classifications to avoid unnecessary inspections or transit delays.
Why Choose Us?
Metric Lab Source is recognized globally as a premier source for high-end research chemicals because we treat scientific integrity as an absolute requirement. When you invest in our 99% pure 1cP-AL-LAD 150mcg Blotters, you are buying a fully verified analytical standard backed by transparent data. We match our chemical purity with logistics excellence, combining prompt international dispatch, cutting-edge stealth packaging systems, and a professional, scientifically literate customer support framework to assist you with bulk ordering or regulatory questions. We supply the tools that allow your research team to innovate with total confidence.
Frequently Asked Questions (FAQ)
What is 1cP-AL-LAD 150mcg Blotters used for in research?
In professional laboratory environments, 1cP-AL-LAD 150mcg Blotters are used as an analytical reference standard to evaluate in vitro receptor affinity at 5-HT pathways, conduct controlled structural binding studies, map structure-activity relationships (SAR) within novel lysergamides, and calibrate advanced chromatographic equipment.
Is 1cP-AL-LAD 150mcg Blotters legal to purchase for scientific study?
The legality of 1cP-AL-LAD 150mcg Blotters depends completely on the specific analogue acts, controlled substance regulations, and chemical import laws of your country or state. It is the sole responsibility of the purchasing institution or principal investigator to verify compliance with local laws prior to placing an order.
How discreet is shipping?
We maintain an absolute standard of operational confidentiality. All orders are safely vacuum-sealed inside robust, non-transparent multi-layer barriers and shipped in entirely plain outer boxes or bubble mailers. There are no mentions of chemical names, precise blotter sheets, dosages, or company branding on the exterior label.
What is the purity level?
We guarantee a minimum purity threshold of 99.0% for the active raw compound prior to its deposition onto the cellulose carrier matrix. This high-tier baseline prevents structural impurities or synthesis leftovers from introducing unexpected variables into your experimental data arrays.
How is that tested?
Every production lot undergoes an extensive quality check sequence. We verify chemical identity and active core purity by executing High-Performance Liquid Chromatography (HPLC), Mass Spectrometry (MS), and Nuclear Magnetic Resonance (NMR) spectroscopy before completing the shipping process.
